Test desk configuration
DS30 link
DS30 link
Digital
network
DS30 link
Station testing
Station testing helps to determine if a station functions correctly while the
station connects to a loop and a line circuit group. Station testing occurs
under the line maintenance subsystem (LNS) at the MAP terminal or from a
station. The testing occurs from a station in the events of the station ringer
and short circuit tests that you can dial. Stations tests are manual. Results
from station tests must return to the station.
The system does not support the silent switchman test because a subscriber
loop in cutoff interferes with the ringing.
TM
Input/
or
Tip, ring, sleeve, ground
output
RMM
test
or
trunk
RSM
Applique 2
SD
MTM
MD
TTU
SMS
DMS-100 Family SMS Maintenance Manual XPM10 and up
Trouble isolation and correction 9-37
Horizontal
Test access
test pair
network
DS-1 link
RCS
MLT
Vertical test pair
CTU