7-98 Card replacement procedures
NT6X86
SMS
(continued)
14
15
16
17
297-8231-550 Standard 09.01 August 1998
Use the following information to determine what step to go to next in this
procedure.
If you entered this procedure
from
alarm clearing procedures
other
Test the inactive unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If TST
passed
failed
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If RTS
passed
failed
Return to the maintenance procedure that directed you to this procedure. At
the point where a faulty card list was produced, identify the next faulty card on
the list and go to the appropriate card replacement procedure for that card in
this manual.
Do
step 17
step 15
Do
step 16
step 17
Do
step 19
step 18