Nortel DMS-100 Series Maintenance Manual page 216

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-10 Card replacement procedures
NT2X70
SMS
(continued)
15
297-8231-550 Standard 09.01 August 1998
a.
Using your fingers or thumbs, push on the upper and lower edges of the
faceplate to ensure the card is fully seated in the shelf.
b.
Simultaneously rotate the top latch downward and the bottom latch upward.
The card will lock into position when the lock-latches are flush with the
faceplate of the card.
Power up the inactive SMS unit as follows:
a.
Ensure the power converter (NT2X70) is inserted. A major audible alarm
may sound. This alarm is silenced when power is restored to the converter.