Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

unit_no
is the number of the inactive unit
If test
passes
fails, and the system produces a
card list
fails, and the system does not
produce a card list
28
Check the card list that appears at the MAP terminal.
Example of a MAP display:
Site Flr RPos
HOST
00
M07
HOST
00
M07
HOST
00
M07
HOST
00
M07
If you
replaced all the cards on the list
did not replace all the cards on
the list
29
Go to the SMS card replacement procedures section in this document and
replace the next card on the list. Return to this procedure, and go to step 27.
30
To return the inactive unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
If RTS
passes
fails
Bay_id Shf Description Slot EqPEC
SME 00
51
SMS : 000
SME 00
51
SMS : 000
SME 00
65
SMS : 000
SME 00
51
SMS : 000
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-15
major
(continued)
Do
step 30
step 28
step 37
08
6X45
22
6X40
22
6X40
12
6X45
Do
step 37
step 29
Do
step 38
step 37
PM SMS
FW-xxxxx