Clearing An Rcs Alarm - Nortel DMS-100 Series Maintenance Manual

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an SMS alarm
Alarm condition
Minor

Clearing an RCS alarm

Faults that occur in a remote concentrator SLC-96 (RCS) raise an alarm.
The system sends these alarms to the log subsystem as PM128 logs at the
MAP terminal. The PM128 logs contain the reasons for the alarms and
actions to follow to clear the alarm. The Clearing an SMS alarm table
contains this information.
(continued)
Possible cause
Non-software cards have
faults.
DMS-100 Family SMS Maintenance Manual XPM10 and up
—end—
Troubleshooting chart 10-5
Action
Proceed as follows:
1
Silence the alarm.
2
Identify the SMS unit in
the ISTb condition.
3
Post the SMS unit in the
ISTb condition.
4
Identify the problems with
the posted SMS unit.
5
Busy and test the posted
SMS unit.
6
Return to service the
posted SMS unit.