Nortel DMS-100 Series Maintenance Manual page 61

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Diagnostic name and description
Diagnostic name (mnemonic)
PS SPCH
SMSAB
SMS MSG
SPCH DG
SYNC DG
TONE DG
TS DIAG
UTRDIAG
The system stores a REx maintenance record for each XPM that contains the
following information:
REx scheduler, if the XPM is in the system
date/time and result (passed/failed) of the last REx
failure reason, diagnostics failures, and a list of defective cards (if it
applies) if the last REx failed
date/time of previous failed REx
date/time of first passed REx after a previous failure
The following restrictions apply to REx tests:
The system REx (SREx) controller only runs REx on one XPM at a time
if the office uses the NT-40 processor. Super Node supports REx tests
that run in order for a maximum of ten XPMs with the same REx test
class.
For REx to run, the node must be one of the following:
— InSv
— ISTb because of a REx test failure
— in-service trouble because P-side DS-1 links are out-of-service.
If the system cannot start a Warm SWACT, REx terminates.
After correct completion of REx, the XPM has a new active unit,
because of the SWACT.
(continued)
—end—
DMS-100 Family SMS Maintenance Manual XPM10 and up
Maintenance overview 1-45
Description of diagnostic
P–side Speech Links
6x81 A/B Bits
SMS A/B DDL Msg
Speech Path
Sync Diag
Tone Diag
Time Switch Diag
UTR Card