Nortel DMS-100 Series Maintenance Manual page 478

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

A --14 Appendix
CKT TYPE
==============================================================
1MR
Number of entities in the posted set: 1
> post l ercs 0 0 0 1 print
CKT TYPE
==============================================================
OWT
Number of entities in the posted set: 1
> pmdebug sms 0
PMDEBUG MODE - CONNECTING TO SMS 0 UNIT 1
WARNING: You now have access to the PM monitor...proceed with
caution
LTCUP>
TIme,TAsk,Load,Xprompt,CHEaptmr,DAtadump,Uspace,Debug,BPMonito
r,Swerr,C++monitor,Ipc,Verreg,Patches,Flq,Msg6x69,UArtimc,Newm
sging,NWmsgtrc,MSGTr,Chnls,CDm,DYnamic,MTc,Rcvrmon,SChnls,CSm,
DS1,CMr,UTr,OMUnsol,DIagnose,IMage,Audit,MAtediag,CAudit,PRfm,
PErcall,Bigfoot,PARaudt,CP,CNd,Trmtrc,SMsm,SMSS,LTst.
We can now dump the line config status from PMDEBUG for RT 1. This is
ERCS0 0 which is the same SLC on which we have been working. This can be
verified by matching the node number of 235. We see that the SMS is reporting
that line 0 on the A shelf is equipped and line 1 on the A shelf is unequipped.
This agrees with what the CM shows when posting the line.
LTCUP> sm
Rt config, All chnl bsy, pWrk trc, aBbt, Set ln config
Disp ln config status, disp ln config Image
cHnl aud, send Cfield msg, Line, sMsr, *
UP:SMsm> d 1
OPEN WRITING XPMTLC0001SMS.AA02 2000/04/13 11:31:50
LEN
ERCS 00 0 00 00
LEN
ERCS 00 0 00 01
DN
STATE FAIL
619 351 1234 IDL
DN
STATE FAIL
619 516 1212 LMB
EqPEC
SCD203
EqPEC
SCD203

Advertisement

Table of Contents
loading