Nortel DMS-100 Series Maintenance Manual page 149

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Repeat this procedure for the other link.
5 To post and offline the remote to change to Mode II, type
>MAPCI;MTC;PM
>POST RCS rcs no
>BSY
>OFFL
Example:
>MAPCI;MTC;PM
>POST REM1 00 2
>BSY
"CALLS WILL BE AFFECTED.
>YES
>OFFL
6 In table RCSINV, to delete the protection links from REM1 00 1 and
REM1 00 3, type
>TABLE RCSINV
>POS rcs no
>CHA
Example:
>TABLE RCSINV
>POS REM1 00 1
>CHA
Step through the fields until the PROT field appears. Press the ENTER
key to step through the fields.
PROT:
Y
>N
Converting from Mode I to Mode II 4-13
PLEASE CONFIRM (YES OR NO)"