Nortel DMS-100 Series Maintenance Manual page 231

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the front of the shelf
23
Reseat the NT6X40 card unseated in step 12. Go to step 25.
Replace the card using the procedure " Removng and replacing a card " in this
24
section. When you have completed the procedure, return to this point.
At the MAP terminal
25
The next action depends on the type of network in the office.
If you are working on
JNET
ENET
26
Return to service one of the network links by typing
>RTS plane_no link_no
and pressing the Enter key.
where
plane_no
is the number of the plane (0 or 1) for the link
link_no
is the link number (0 to 63)
If the link
returned to service and there are
more manual-busy links
returned to service and there are
no more manual-busy links
did not return to service
27
Repeat step 26 for each manually busy C-side link. When you have
successfully returned all C-side links to service, go to step 29.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Card replacement procedures 7-25
in a SMS
Do
step 26
step 28
Do
step 27
step 29
step 35
NT6X40
(continued)