Nortel DMS-100 Series Maintenance Manual page 168

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-4 Alarm clearing procedures
PM SMS
PM SMS
critical
critical
(continued)
(end)
Clearing a PM SMS critical alarm
At the MAP terminal
1
2
3
4
5
297-8231-550 Standard 09.01 August 1998
To access the MTC level and silence the alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level and identify the SMS module that is in a critical state,
type
>PM;DISP STATE SYSB SMS
and press the Enter key.
Example of a MAP response:
SMS 0
To post SysB SMS, type
>POST SMS sms_no
and press the Enter key.
where
sms_no
is 0–127 for an NT40 and 0–255 for the DMS SuperNode.
Example of a MAP response
SMS
SysB
PM
1
SMS
1
SMS
0
SysB
Links_OOS:
Unit
0: InAct
Unit
1: Act
To identify the problems with the posted SMS, type
>QUERYPM FLT
and press the Enter key.
Proceed immediately to the SMS recovery procedures section in this
document.
ManB
OffL
CBsy
0
10
0
0
CSide
0, PSide 0
SysB
SysB
ISTb
InSv
0
0
130
0
0
4

Advertisement

Table of Contents
loading