Nortel DMS-100 Series Maintenance Manual page 473

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

0. We also know from our line to DS0 associated that line 0 signaling
information should be in timeslot (chnl) 0 and that line 1 signaling information
should be in chnl 2 location. Reference Table 1). Both lines are reporting
onhook, which is expected for an IDLE equipped line. Note: Be very careful
here in that the port number entered ranges from 0 to 19 and is entered as a
HEX value (port 19 would be entered as 13).
LTCUP> smss
A/bdata, Ddldata, Tsw, Psport, Rtstat, psW, Cmb, Mtc, aLms, *
UP:SMSS> a
Chnl blk, Image, port Map, Bits, sAn, Digit, Outg, Uneq scan, *
UP:SMSS> b 0
Chnl 00
on hook
Chnl 01
on hook
Chnl 02
on hook
Chnl 03
on hook
Chnl 04
on hook
Chnl 05
on hook
Chnl 06
on hook
Chnl 07
on hook
Chnl 08
unequiped
Chnl 09
on hook
Chnl 0A
unequiped
Chnl 0B
on hook
Chnl blk, Image, port Map, Bits, sAn, Digit, Outg, Uneq scan, *
UP:SMSS>
Now we check to see what the SMS is expecting to see from the SLC-96. For
an IDLE line, we are scanning for an offhook signaling pattern. Note: The port
number ranges from 0 to 19 and the port number ranges from 0 to 23. Both
values are entered as the HEX equivalent values.
Chnl blk, Image, port Map, Bits, sAn, Digit, Outg, Uneq scan, *
UP:SMSS c 0 0
mode: scan off-hook
timer blk not attached
Chnl blk, Image, port Map, Bits, sAn, Digit, Outg, Uneq scan, *
UP:SMSS c 0 2
Chnl 0C
on hook
Chnl 0D
unequipped
Chnl 0E
on hook
Chnl 0F
unequipped
Chnl 10
on hook
Chnl 11
on hook
Chnl 12
on hook
Chnl 13
unequipped
Chnl 14
on hook
Chnl 15
on hook
Chnl 16
on hook
Chnl 17
on hook
flash option: false
XPMTLC0001SMS XPM_PARTITION MICA
Appendix A --9