To switch the activity of the unit, type
>YES
and press the Enter key.
The system runs a pre-SWACT audit to determine the ability of the inactive unit
to accept activity.
Note: A maintenance flag (Mtce) appears when maintenance tasks are in
progress. Wait until the flag disappears then proceed with the next
maintenance action.
If the message
is SwAct passed
is SwAct failed Reason:
SMS SwActback
is SwAct refused by SwAct
controller
42
To force a switch of activity to the active unit, type
>SWACT FORCE
and press the Enter key.
The SWACT controller can use short term history reasons to refuse the
SWACT. When the SWACT is complete, the short term history reasons are
reset.
43
Go to step 10 to clear the alarm condition on the newly inactive unit.
44
The procedure is complete. If other alarms appear at the MAP display, refer to
the appropriate alarm clearing procedures.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-19
major
major
(continued)
Do
step 43
step 42
step 42
PM SMS
PM SMS
(end)