7-116 Card replacement procedures
NT7X05
SMS
(continued)
15
16
17
18
19
297-8231-550 Standard 09.01 August 1998
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the SMS unit (0 or 1) tested in step 14
If TST
passed
failed
Load the 7X05 card in the inactive SMS unit by typing
>XPMSTOR INACTIVE CC [loadfile_name]
and pressing the Enter key.
where
file_name
is an optional source file name, if not included the file name in
the field LOAD in table LTCINV will be used.
If load
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 20.
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.