Nortel DMS-100 Series Maintenance Manual page 292

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-86 Card replacement procedures
NT6X85
SMS
(continued)
9
10
At the frame
11
12
297-8231-550 Standard 09.01 August 1998
Access the PM level of the MAP display by typing
>PM;POST SMS sms_no
and pressing the Enter key.
where
sms_no
is 0–127 for NT40 and 0–255 for DMS SuperNode
Example of a MAP response
SMS
3
INSV
Unit0
Act
Unit1
Inact
Busy all links connected to the faulty NT6X85 card by typing
>BSY LINK link_no
and pressing the Enter key.
where
link no
is the number of the link connected to the faulty NT6X85 card
Repeat this command for each link to the faulty card.
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and
connect it to the wrist strap grounding point on the left
side of the frame supervisory panel of the SMS. This
protects the equipment against damage caused by
static electricity. Do not replace more than one
NT6X85 card at a time.
Put on a wrist strap.
WARNING
Equipment damage
When removing or inserting a card, do not apply
direct pressure to the components and do not force the
cards into the slots.
LINKS_OOS
CSIDE 0
InSv
ISTb
PSIDE 2