Nortel DMS-100 Series Maintenance Manual page 198

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-34 Alarm clearing procedures
PM SMS
minor
(continued)
40
41
42
43
297-8231-550 Standard 09.01 August 1998
To test the link busy in step 39, type
>TST LINK link_no
and press the Enter key.
where
link_no
is the number of the link busy in step 39
If test
passes
fails, and the system generates a
card list
fails, and the system does not
generate a card list
Check the card list that appears on the MAP screen. The card that can have
defects appears first on the list.
Example of a MAP display:
Site Flr RPos
HOST
00
M07
HOST
00
M07
If cards
are replaced
are not replaced
Go to the SMS card replacement procedures section in this document for the
next card on the list. When you return from the card replacement procedures,
go to step 39 of this procedure.
To return the link to service, type
>RTS LINK link_no
and press the Enter key.
Bay_id Shf Description Slot EqPEC
SME 00
51
SMS : 000
SME 00
51
SMS : 000
Do
step 43
step 41
step 45
01
6X85
05
6X85
Do
step 45
step 42