Nortel DMS-100 Series Maintenance Manual page 239

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

10
Set the PM to the ROM level by typing
>PMRESET UNIT unit_no NORUN
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
At the frame
11
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and
connect it to the wrist strap grounding point on the left
side of the frame supervisory panel of the SMS. This
protects the equipment against damage caused by
static electricity.
Put on a wrist strap.
12
WARNING
Equipment damage
When removing or inserting a card, do not apply
direct pressure to the components and do not force the
cards into the slots.
Remove the NT6X41 card as shown in the following figures.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Card replacement procedures 7-33
SMS
NT6X41
(continued)