Nortel DMS-100 Series Maintenance Manual page 277

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

If load
passed
failed
11
Test the CMR card by typing
>TST UNIT unit_no CMR
and pressing the Enter key.
where
unit_no
is the number of the unit containing the faulty CMR card
If TST
passed
failed
12
Return the CMR card to service by typing
>RTS UNIT unit_no CMR
and pressing the Enter key.
where
unit_no
is the number of the unit containing the faulty CMR card
If RTS
passed
failed
13
Return to the Alarm Clearing Procedures that directed you to this procedure. At
the point where a faulty card list was produced, identify the next faulty card on
the list and go to the appropriate card replacement procedure for that card in
this manual.
14
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Card replacement procedures 7-71
SMS
Do
step 11
step 14
Do
step 12
step 13
Do
step 16
step 14
NT6X78
(continued)