Converting from Mode I to Mode II
Mode I to Mode II conversion
Two procedures follow for conversion from Mode I to Mode II operation.
This conversion can be required to free up DS-1 links to the remote site for
additional SLC-96 systems.
Use the procedure on page 4-3 if at least two links are available (entered as
NILTYPE in table LTCPSINV). The examples in the procedure apply to the
example configuration shown in the following figure. The example shows
that two remote concentrator SLC-96 (RCS) modules in Mode I; KRCS 00 0
can change to Mode II operation.
Example configuration for procedure Mode I to Mode II conversion
(two available links)
Use the procedure on page 4-10 if no links are available. The examples in
the procedure apply to the example configuration shown in the following
figure. The example shows that four RCS modules operating in Mode I;
REM1 00 2 can convert to Mode II.
8
0
2
0
1
KRCS 00 0
Note: Ports 10–19 are not assigned.
DMS-100 Family SMS Maintenance Manual XPM10 and up
SMS 0
DS-1 port (link) designations
4
6
RCS link
2
3
designations
9
7
1
3
5
0
1
2
3
KRCS 00 1
4-1