Nortel DMS-100 Series Maintenance Manual page 142

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

4-6 Converting from Mode I to Mode II
6 The remote changed to Mode II. The four links used earlier in Mode I
297-8231-550 Standard 09.01 August 1998
>$
LOOPTEST:
>N
SHLFGRPMODE: MODE1
>MODE2
PORT:
4
> 12
PORT:
6
>$
LOOPTEST:
>N
Step through the fields that remain until the tuple to change appears.
Press the Enter key to step through the fields that remain.
KRCS
00 0 MIS 1
MODE2
(10)$ N
N
ENTER Y TO CONFIRM, N TO REJECT OR E TO EDIT.
>Y
WARNING:
Static data not updated for SMS 0
You must BSY and RTS the SMS
TUPLE CHANGED
JOURNAL FILE INACTIVE
operation are free. Enter table RCSINV again. Assign the PORT
numbers again to any two of the four free links. (In the example, links 4
and 6 are assigned again.)
>POS rcs no
>CHA
>QUIT
Example:
>TABLE RCSINV
>POS KRCS 00 0
0
1
C
8
NOLOAD
MODE2
(12)$ N
MISC_ALARM
MAJOR 35 DAVIS DRIVE RTP
SMS 0
S
WP1B
Y
8