ECT RESISTANCE VALUES

• Measure between the two pins on the ETC sensor to find the resistance value.
Measure the resistance value of the meter leads by touching the ends together, and subtract this value from the
°F (°C)
Nominal Reading (kΩ)
-40 (-40)
45.313 kΩ
22 (-30)
26.114 kΩ
-4 (-20)
15.462 kΩ
14 (-10)
9.397 kΩ
32 (0)
5.896 kΩ
50 (10)
3.792 kΩ
68 (20)
2.500 kΩ
86 (30)
2.057 kΩ
104 (40)
1.175 kΩ
122 (50)
0.834 kΩ
140 (60)
0.596 kΩ
158 (70)
0.435 kΩ
176 (80)
0.323 kΩ
194 (90)
0.243 kΩ
212 (100)
0.186 kΩ
230 (110)
0.144 kΩ
248 (120)
0.113 kΩ
266 (130)
0.086 kΩ
284 (140)
0.071 kΩ
9850045 R01 - 2020-2021 RANGER 1000 Service Manual
© Copyright Polaris Inc.
IMPORTANT
sensor value to ensure accurate results.
Minimum Reading (kΩ)
40.490 kΩ
23.580 kΩ
14.096 kΩ
8.642 kΩ
5.466 kΩ
3.542 kΩ
2.351 kΩ
1.941 kΩ
1.118 kΩ
0.798 kΩ
0.573 kΩ
0.421 kΩ
0.313 kΩ
0.237 kΩ
0.182 kΩ
0.140 kΩ
0.109 kΩ
0.086 kΩ
0.068 kΩ
ENGINE ELECTRICAL
Max Ω Reading (kΩ)
50.136 kΩ
28.647 kΩ
16.827 kΩ
10.152 kΩ
6.326 kΩ
4.043 kΩ
2.649 kΩ
2.173 kΩ
1.231 kΩ
0.870 kΩ
0.618 kΩ
0.451 kΩ
0.332 kΩ
0.250 kΩ
0.191 kΩ
0.148 kΩ
0.116 kΩ
0.093 kΩ
0.074 kΩ
4.25