Engine Coolant Temperature Sensor (Etc); Ect Overview; Ect Sensor Test; System Operation Test - Polaris RANGER ETX 2015 Owner's Manual

Table of Contents

Advertisement

FUEL SYSTEM

ENGINE COOLANT TEMPERATURE SENSOR (ETC)

ECT OVERVIEW

Mounted on the cylinder head, the engine temperature
sensor measures coolant temperature. The engine
temperature
sensor
is
Coefficient (NTC) type sensor, as the temperature
increases, the resistance decreases. This signal is
processed by the ECU for determining the fuel and
ignition requirements during operation. The ECU also
uses this signal to determine when to activate the fan.

ECT SENSOR TEST

SYSTEM OPERATION TEST

To quickly rule out other components and wiring related
to the ECT, disconnect the harness from the ECT sensor
and start the engine. After a few seconds, the fan should
turn on and the "Check Engine" indicator should display
on the instrument cluster. This indicates all other
components are working properly.

RESISTANCE VS. TEMPERATURE TEST

CAUTION
Contact with boiling water or steam may cause burns.
1. Disconnect the ECT from the main harness.
2. Remove the ECT.
3. Fill a pot of water 1/2 way with water.
4. Place a pot of water on a hot plate.
5. Place the sensor / tip of a thermometer in the water,
ensure the display is legible as you will reference the
thermometer throughout the test.
4.34
a
Negative
Temperature
9926806 R03 - 2015 - 2016 RANGER ETX / 570 2-SEAT 2015 - 2016 RANGER 570 CREW Service Manual
6. Safely position the ETC so that the sensor is
submerged in water from the threads down and the
connector may be readily probed.
Use a wire or other type of prop to ensure the sensor is
properly supported and the tip of the sensor is touching
water only.
7. Prepare a table similar to the one below, then heat
the water and document the resistance measured
between pin 1 and pin 2 as the water and sensor
warm. If the Sensor tests out of tolerance, the sensor
should be replaced.
ECT Sensor Resistance Readings
TEMPERATURE °F (°C)
68 °F (20 °C)
86 °F (30 °C)
104 °F (40 °C)
122 °F (50 °C)
140 °F (60 °C)
158 °F (70 °C)
176 °F (80 °C)
194 °F (90 °C)
212 °F (100 °C)
NOTE
RESISTANCE
2.5 k Ω ± 6%
1.7 k Ω ± 6%
1.2 k Ω ± 6%
834 Ω ± 6%
596 Ω ± 6%
435 Ω ± 6%
323 Ω ± 6%
243 Ω ± 6%
186 Ω ± 6%
© Copyright Polaris Industries Inc.