VERSION 02/2018
OPERATING MANUAL
Grounding scheme (example)
B_05904
Signal ground
Minimum cable cross-section
AquaCoat cabinet
Conveyor
Spray booth
Spraying stand
Safe operation of the AquaCoat system is only guaranteed with a grounding connection.
Connect all ground cables using a short and direct route.
Tank
All paints, flushing agents and waste tanks have to be made of metal.
All tanks in the cabinet must be connected to the potential equalization. All further
tanks must be grounded.
6.6
SAFETY CHECKS
Carry out safety checks in accordance with Chapter 8.2.3.
ORDER NUMBER DOC 2366717
Floor, static dissipative
4 mm²; AWG 12
16 mm²; AWG 6
16 mm²; AWG 6
16 mm²; AWG 6
Conveyor
R
< 1 MΩ
max.
Spraying stand
Signal ground
Work piece
48