Grounding The Powder Coating System; Safety Checks - WAGNER PER-X1 Translation Of The Original Operating Manual

Robot powder spray gun
Table of Contents

Advertisement

Operating manual Robot powder spray gun PER-X1
6   Assembly and Commissioning
6.7.1   Grounding the powder coating system
1
2
P_04905
1. Only use mains cables with grounding strand!
2. Connect the control unit's grounding cable with the signal ground!
3. Connect grounding cable to an uncoated metal part of the booth!
4. Remove all paint from hooks and other hanger parts!
5. Connect the robot's grounding cable with the signal ground!
6. The floor must be electrostatically conductive!
6.8   SAFETY CHECKS
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned. This includes:
4 Carry out safety checks in accordance with Chapter Safety Checks [8 34].