Changing From Aircoat Round Jet To Aircoat Flat Jet - WAGNER GM5000 Operating Manual

3-in-1 electrostatic, aircoat & airless system
Table of Contents

Advertisement

EDITION 03/2012
OPERATING MANUAL
5.4.5

CHANGING FROM AIRCOAT ROUND JET TO AIRCOAT FLAT JET

1. Flush the spray gun (1) out thoroughly with
cleaning agent.
2. Relieve the pressure of gun and unit.
3. Save the spray gun (1) using the trigger lock.
4. Unscrew round jet nozzle cap (2) incl. nozzle
insert (3).
5. Unscrew nozzle insert (3) using nozzle
spanner (4).
6. Unscrew nozzle nut (5) and remove nozzle
screw connection (7) and sealing nipple (8)
out off the nozzle body (6) and clean all parts
thoroughly.
7. Insert desired ACF 5000 nozzle (11) into the
valve housing.
8. Put the air cap (10) on the nozzle (11) and paying
attention to the position of the guide surfaces.
9. Screw union nut with attached nozzle guard (9) to the
gun body and make sure that the air cap horns lie in the
designated recess (Y).
10. Before tightening the air cap horns (Y) set the desired
jet level and then tighten the union nut to the stop by
hand.
PART NUMBER DOC 2319150
9
Y
1
3
4
5
11
10
GM
5000EAC.
2
8
7
6
1
B_03162
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vm500F230

Table of Contents