CHANGING FROM AIRCOAT ROUND JET TO AIRCOAT FLAT JET

1. Flush the spray gun (1) out thoroughly with
cleaning agent.
2. Relieve the pressure of gun and device.
3. Secure the spray gun (1) using the trigger lock.
4. Unscrew round jet nozzle cap (2) incl. nozzle insert (3).
5. Unscrew nozzle insert (3) using nozzle spanner (4).
6. Unscrew nozzle nut (5) and remove nozzle screw
connection (7) and sealing fi tting (8) out off the
nozzle body (6) and clean all parts thoroughly.
7. Insert desired ACF 5000 nozzle (11) into the valve
housing.
8. Put the air cap (10) on the nozzle (11) and pay
attention to the position of the guide surfaces.
9. Screw union nut with attached nozzle guard (9) to
the gun body and make sure that the air cap horns
lie in the designated recess (Y).
10. Before tightening with the air cap horns (Y), set the
desired jet level and then tighten the union nut to
stop by hand.