Chapter 1 General information

Explanation of technical terms

Technical Term
3-roll system
Adhesive Strings
Air Assist
Air Assist Tube
Air Blast
Application Mode
Applicator
Applying Cycle
Blow-On
Cycle
Default
Dancer Arm
Display
Display-Controller
Edge Detection
Factory Setting
HMI
Home Position
Home-Position-Sensor
Hotline
Version: 30.01.15
Explanation
Is used for label around of rouns products.
Leaked adhesive at the label edge may adhere the label at
the label liner. The printed label adheres to the liner and can
thus not be fed to the Tamp.
A stream of air pushing against the bottom of the Tamp/blow
box during label feed until label is fixed by vacuum.
The air assist tube directs air assist by one or more drillings
to the bottom side of the label. It is mounted in the section of
the peeler bar and can be adjusted.
The streams of air effusing from the Tamp drill holes during
labeling in order to blow the label by air pressure onto the
product (blow box by tube nozzles).
see explanations: Tamp On, Tamp Blow, Blow On.
Description for label applicator respectively mimic that moves
the Tamp.
An entire working sequence of the labeler ((e.g. print label if
applicable), peeling off the label and feeding the label to the
applicator up to product labeling).
A contact free application mode in which the Tamp takes the
printed label by a stationary vacuum grid and applies with air
pressure without moving the Tamp.
Sequence of a labeling procedure, from product detection to
product labeling until the Tamp arrives in home position.
See factory setting.
Arm, tensing the label web via spring tension.
Display providing information on status for the user.
Controller with integrated display for text information (s. Dis-
play) and key panel for operation and programming.
The edge (front or back) of a product or label that will cause
the detector to send a detection signal.
Comprises all basic adjustments of the system after manufac-
turing which may differ from the condition after a system set-
up. Software parameters are reset by a reset to the factory
setting (default values) and formerly adjusted values are lost.
Abbreviation for Human-Labeling Station-Interface, input de-
vice for a labeling station or for a controller of components.
Basic or home position of the Tamp at the peeler bar.
Sensor for detection of home position when the Tamp is in
home position.
Customer support for a fast diagnosis by phone.