Chapter 6 Installation and initial startup
Information on balancing of label sensor to label
If the Teach-In-button is pushed longer than 6 seconds, the bright/dark detection (NO/NC)
is switched over at the sensor. For balancing of the label, push the Teach-In button only 2
seconds.
Nr.
1
2
Requirements
Label web is inserted
No transportation of products
Labeling system is turned on
Instruction
How to teach the label gap sensor to the product.
Step
1
2
3
4
Version: 30.01.15
Description
TEACH-IN BUTTON
LED DISPLAY
Procedure
Push the Teach-button for 2 seconds, until the LED flashes up continuously.
Guide in the following 2-8 seconds the label web with at least 2 labels
through the sensor fork. The LED signalizes the teach-procedure by a fast
flashing frequency.
After teach-procedure the LED informs by flashing about the result.
2x Flashing  teach-Procedure is terminated successfully.
4x Flashing  teach-Procedure was not terminated successfully, repeat the
teach-procedure.
Arrange then a label calibration (see p. 48).
Page 35 of 97
40020664 Geset 141
Fig. 6-3 Balance label