Chapter 8 Operation

122 HOME TIMEOUT

This adjustment determines the maximum time the applicator waits for the signal of the
home position sensor during retraction movement before an error message is indicated.
This is also valid after switching on the labeler in case the tamp does not move to home
position because e.g. air pressure has not yet been connected.
CONFIGURATION
HOME TIMEOUT
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value (unit =
value x 100ms, value "000" = no query of home position, value "255" = waits in-
definitely for home position signal)
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.

123 BARCODE READ TIME

This adjustment determines the maximum time the applicator waits for the signal of the
BARCODE reader before an error message is indicated.
CONFIGURATION
BARCODE READ TIME
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value (unit =
value x 100ms, value "000" = no query of home position, value "255" = waits in-
definitely for home position signal).
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.
Version: 30.01.15
122
000
123
000
Page 80 of 97
40020664 Geset 141
GB