Chapter 8 Operation

112 CALIBRATE LABEL (CALIBRATE LABEL)

This function is used to perform an automatic label calibration. An application of several
labels takes place. Thereby parameters like label position and label length will be deter-
mined. If a calibration is successfully finished, the values will be indicated in the second
line. If the calibration is not finished successfully, "CALIBRATE LABEL" remains in the
second line and the process will have to be repeated.
CONFIGURATION
CALIBRATE LABEL
Press [Enter] to start calibration.
Press [Start] or [Stop] to exit the parameter setting.

113 VACUUM LEVEL

This parameter determines the threshold for label presence detection on tamp. A value of
0 to 255 can be entered. If the value "003" is entered a sufficient vacuum check is real-
ized. Values beyond, belong to the sensitive or high-sensitive measure range. If the value
is adjusted to 000, there is no vacuum check active.
CONFIGURATION
VACUUM LEVEL
Press [Enter] to edit the configuration parameter.
Press then the buttons [] or [] to increase or reduce the value. (unit = value x
1/33 bar).
Press [Enter] to confirm the entry
Press [Start] or [Stop] to exit the parameter setting.