Chapter 6 Installation and initial startup

Overview of the connections

The labeling station provides different electrical connections depending on machine confi-
guration that are located laterally at the cabinet.
No.
1
2
3
4
5
6
7
8
9
10
11
Version: 30.01.15
Description
(X8) APPLICATOR  DRIVE UNIT  INSTALLED FIX
(X6) ALARM LAMP
(X2) PRODUCT SENSOR 1  FOOT SWITCH
(X7) LABEL SENSOR
USB
(X5) ENCODER  DISABLED
(X9) I/O
(X10) HMI
(X3) LOW LABEL
ON- / OFF SWITCH
MAINS SUPPLY
Page 32 of 97
40020664 Geset 141
Fig. 6-1 Electrical connections