Chapter 8 Operation
CONFIGURATION
BLOW-TRIGGER
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value. (valid
range: 000-032).
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.

120 BLOW DELAY (BLOW DELAY)

This configuration parameter delays the blow-off by the adjusted value. The adjustment
will be ignored when the previous parameter 119 „BLOW TRIGGER" is set on "000".
CONFIGURATION
BLOW DELAY
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value. (unit =
value x 10ms, value "000" = no delay).
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.
121 BLOW TIME
The blow time and thus the duration of the blow-off valve`s activation for the transfer of
the label on to the product is determined. The allowed range is between 010 and 255
(value x 1ms).
CONFIGURATION
BLOW TIME
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value. (unit =
value x 1ms, value "000" Tamp-On mode).
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.
Version: 30.01.15
119
000
120
000
121
000
Page 79 of 97
40020664 Geset 141