107 Label Trigger (Label Trigger) - Weber Geset 141 Original User Manual

Table of Contents

Advertisement

Chapter 8 Operation

107 LABEL TRIGGER (LABEL TRIGGER)

Herewith it is determined which sensor input and what kind of signal generates the start
signal for labeling. The functions are combined with each other with the help of arithmetic
sum or are activated separately.
CONFIGURATION
LABEL TRIGGER
Press [Enter] to edit the configuration parameter
Press either [] or []to increase or reduce the value.
Press [Enter] to confirm the entry
Press [Start] or [Stop] to exit the parameter setting.
Parameter Function
The first (primary) product sensor input is selected as start sensor.
001
002
The second (secondary) product sensor input is selected as start sensor.
+4
As start signal not a switching edge is used but an input level.
As long as an input level is available, the application cycle is repeated.
This enables e. g. the multiple labeling of products with different lengths.
A start signal is only accepted after terminated labeling applying cycle for an again
+8
label application. If the label applying cycle is not yet terminated, an early start
signal leads to error message E07. This function cannot be combined with param-
eter +004.
+16
Selects leading edge as starting signal.
+32
Enables the connection of a NPN sensor as start signal-sensors. (Standard is a
PNP sensor).
Version: 30.01.15