Chapter 6 Installation and initial startup

(X3) Low Label Sensor (Option)

The reflective sensor scans the label roll. A signal is fowarded, if the label roll under-runs
a certain diameter. In connection with the 3-colored alarm option the signal is shown by
the yellow lamp. The labeler remains ready for use until the programmed remaining label
length has run out. Then the labeler changes to error condition and stops.
Information on adjustment of reflective sensor
No.
1
2
3
4
Requirements
¥
The sensor for low label warning is installed.
¥
Label roll
¥
No transportation of products
¥
Labeler is ready for operation
Required equipment
¥
Hexagon socket wrench
¥
Screw driver
Instructions
Please adjust the low label prewarning as follows.
Step
1
2
Version: 30.01.15
Description
SCREWS FOR ADJUSTMENT
TABLE DISC
SENSOR
RANGE OF HEADLIGHTS' ADJUSTMENT
Procedure
Turn the table disc (Pos. 2, Fig. 6-6) so that the light beam of the sensor
(Pos. 3, Fig. 6-6 lights between the gaps.
Turn with the screw driver the range of headlights adjustment (Pos. 4, Fig.
6-6) counter clockwise down until the label roll is not detected anymore by the
sensor (display LED goes out).