Chapter 8 Operation

110 SYNC PULSE TIME (SYNC PULSE TIME)

Herewith the duration of the synchronization output signal is determined. This signal
serves for triggering further peripheries like rotating tamp, printer etc. The signal is acti-
vated for the adjusted time at the end of an applying cycle. The time can be adjusted from
1 up to 255ms. The pulse time is corresponding to each entered value x 10ms. If the value
is set on "000" and the SYNC PULSE DELAY 111 as well on zero. The SYNC signal will
be activated with the beginning of the applying cycle and deactivated at the end of the ap-
plying cycle.
CONFIGURATION
SYNC PULSE TIME:
Press [Enter] to edit the configuration parameter.
Press either [] or [] to increase or reduce the value.
Press [Enter] to confirm the entry.
Press [Start] or [Stop] to exit the parameter setting.

111 SYNC PULSE DELAY (SYNC PULSE DELAY)

With this option, the duration of a delay of the synchronization output signal after the label-
ing procedure is determined. It is used to calibrate the triggering of further peripherals like
rotating tamp, printer aso. The duration can be adjusted from 0 until 255ms. The length of
the pulse corresponds to the entered value x 10 ms. If the SYNC-PULSE TIME is set to
"000", this function can be used to evaluate „Labeling cycle in progress".
CONFIGURATION
SYNC PULSE DELAY
Press [Enter] to edit the configuration parameter.
Press either [] or [] to increase or reduce the value.
Press [Enter] to confirm the entry
Press [Start] or [Stop] to exit the parameter setting.
Version: 30.01.15
110
000
111
000
Page 73 of 97