Chapter 6 Installation and initial startup

(X9) I/O-Signal interface (Option)

The I/O interface serves for the connection of the labeling station with new machine op-
tions or the customer`s controller. The PIN 4 is not used for the external trigger. It has the
same function as the [Start] button of the HMI Panel. A signal will be activated and maybe
failure messages will be reset by pushing.
No.
1
2
3
4
5
6
7
8
Version: 30.01.15
* All outputs which are supplied via (P 24) are not alowed to consume together more than max. 500mA
Description
OUTPUT SIGNAL: READY, (N.O.) MAX. 200MA, MAX. 30V
OUTPUT SIGNAL: LOW LABEL SENSOR, (N.O.) MAX. 200MA, MAX. 30V
OUTPUT SIGNAL: SYNC, (N.O.) MAX. 200MA, MAX. 30V
INPUT SIGNAL: REMOTE START MAX. 10MA, LOW < 3VDC, HIGH > 15VDC
COM INPUT SIGNAL
COM OUTPUT SIGNAL
+24V (P24)
0V TO EARTH
Page 41 of 97
40020664 Geset 141
Fig. 6-9 PIN assignment X9 I/O