115 Extension Trigger (Extens. Trigger) - Weber Geset 141 Original User Manual

Table of Contents

Advertisement

Chapter 8 Operation

115 EXTENSION TRIGGER (EXTENS. TRIGGER)

Herewith the trigger signal for the extension of the applicator is parameterized. After the
label was detected at the tamp, the date is in the labeling cycle at which the trigger is ex-
pected.
Parame-
Connection
ter
value
00
01
Product Sensor 1 (J14)
02
Product Sensor 2 (J9)
03
Aux.-input at I/O-interface: J16
04
Applicator J3
05
Product Sensor 1 (J14)
29 - 32
No permitted parameterization
CONFIGURATION
EXTENS. TRIGGER
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value (valid
range: 000-032).
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.
Version: 30.01.15
Function
Immediate extension of applicator.
Edge triggering (leading edge):
Triggering in case of a rising edge, means
the change from "low" to "high". Only in case
of indication "Wait Trig." A trigger is accept-
ed. Outside this phase all triggers are ig-
nored.
Level triggering (leading edge):
Triggering in case of "high"-signal. Repeti-
tion of applying cycle as long as signal is
active (high).
115
000
Page 76 of 97
40020664 Geset 141
GB