Configuration Interfaces; (X7) Label Sensor; Positioning And Adjustment Label Sensor - Weber Geset 141 Original User Manual

Table of Contents

Advertisement

Chapter 6 Installation and initial startup

Configuration interfaces

(X7) Label Sensor

The label sensor is used for label detection.

Positioning and adjustment label sensor

Information on positioning of label sensor
If the detection of the label's leading edge should be problematic during calibration , the
sensor will be positioned on a possbily free (non-printed) area of the label. Thus, a meas-
urement error is avoided by the alternation of light and dark in a printed area. The sensor
is moved to the „straightest" label edge (diagonally) at a cut-out label.
No.
1
2
3
Requirements
Label web is inserted.
No transportation of products.
Power supply is off (in „0"-position).
Required equipment
Hexagon socket wrench
Instruction
Please position the sensor as follows.
Step
1
2
3
Version: 30.01.15
Description
LABEL WEB
DIRECTION OF THE ADJUSTMENT
LABEL GAP SENSOR
Procedure
Loosen both screws under the sensor's bracket.
Move the sensor to desired position and tighten again the screws.
Arrange then a label calibration (see p. 48).
Page 34 of 97
40020664 Geset 141
Fig. 6-2 Positioning label sensor Oguti