124 Cycle Option - Weber Geset 141 Original User Manual

Table of Contents

Advertisement

Chapter 8 Operation

124 CYCLE OPTION

Pre-defined program processes can be selected here. The processes can be combined or
activated separately with the help of arithmetic sums:
Parameter
Function
No program sequence selected.
000
Deactivates the timeout "variable stroke" and generates an error if the label is lost dur-
+ 001
ing tamp movement (vacuum loss).
Delays the tamp retraction at the end of a blow-off sequence (normally the tamp
+ 002
moves back concurrently with the blow-off valve's activation).
Deactivates the timeout "variable stroke" and ignores vacuum loss during tamp
+ 004
movement.
Activates corner wrap application function for systems with 90°-180° rotating tamp (op-
+ 008
tion).
Activates the vacuum or rather "label on pad" query after label transfer (during tamp
+ 016
retraction) in case of Tamp-On mode (if blow time = "000").
Activates the function for the control of RFID reject unit.
+ 032
D
eactivates the error "timeout label" (useful function to correct errors of vacuum, to
+ 064
switch-off the vacuum check).
Deactivates the timeout-error in case of variable stroke.
+ 128
CONFIGURATION
CYCLE OPTION
Press [Enter] to edit the configuration parameter.
Push the *buttons [] or [] to increase or reduce the parameter value (value:
"000" = no program sequence selected, "001" = 1
tion, "003" = 1
Press [Enter] to save the value.
Press [Start] or [Stop] to exit the parameter setting.
Version: 30.01.15
st
nd
and 2
function...)
Page 81 of 97
124
000
st
function; "002" = 2
40020664 Geset 141
nd
func-
GB