Error Messages By Display - Weber Geset 141 Original User Manual

Table of Contents

Advertisement

Chapter 10 Troubleshooting
The label is beveled on the product.
Correct the labeling result as follows:
Step
1

Error messages by display

As soon as an error was detected at the labeler, the labeling station stops the application
cycle. The labeler changes to standby-mode, the green LED at operator panel goes out
and the red LED lights. In the second line of the display an error message is indicated. Its
meaning is described as follows:
DISPLAY MESSAGE
NOT RESPONDING
PARAMETERS ERROR
TRIGGER ERROR
L. EDGE NOT FOUND
Reset error after troubleshooting by pushing the [Start] or [Stop ] button.
Version: 30.01.15
Procedure
The inclination of the tamp plate may be adjusted incorrectly. Examine and
correct the inclination of the tamp plate.
DESCRIPTION
This message indicates in-
ternal communication prob-
lems between controller and
motor control.
The memory-test when
switching on the controller
resulted in a checksum error.
The trigger for application
comes during application
cycle.
The label sensor does not
detect label material.
Page 95 of 97
40020664 Geset 141
Fig. 10-3: Product with beveled label
CAUSE/ SOLUTION
Possible cause can be loose
cable connections (inside and
outside of the controller) or strong
magnetic fields in the environ-
ment. If necessary, please let
check by qualified personnel...
Activated parameters might be
damaged. If the error is still indi-
cated after a new memory test, a
chip in the controller is probably
damaged. Please contact the
Service Hotline (see page 8).
Increase the distance between
the products or increase the ac-
celeration ramps.
Check the setting of the sensor
for label detection.
Check whether there are labels
on the label liner.