Chapter 8 Operation

Indication of firmware version

The current firmware version (firmware = operating system) of the controller is displayed.

Current configuration set

The Geset 141 provides the opportunity to store resp. call up in memory up to 9 different
configuration sets. Each set can be used for an individual parameterization of the labeler
(e.g. for different label sizes).

Label length

The adjusted label length in [cm] is shown.

Label position

The current value in [cm] to label position is shown.

Label application speed

Currently adjusted speed that a label is fed with.

Label counter

The number with 5 digits indicates the number of the completely performed application
cycles of one operation phase. The counter is reset to "0000" automatically when switch-
ing on the machine. If a negative number with 4 digits is displayed, the counter works in
"Countdown" mode.

Status line

The status line keeps you informed about the current conditions of the labeler and its ac-
tivities. (Details see error-/status messages in chapter Troubleshooting). In labeling opera-
tion the status line provides at one glance the four most important information on current
configuration set.

Error reset

By pushing [Start] or [Stop] button the current error messages are reset assuming that the
reason for the error was corrected.

STAND-BY-Mode

After interruption of the labeling operation (e.g. [Stop]-button was pushed, failure is avail-
able) the labeler changes to Stand-by mode. A menu in the applicator's controller can only
be selected from Stand-by mode. If no error message is available, "STAND-BY" appears
in display.
ALPHA.04
STAND-BY
Version: 30.01.15
0000
Page 59 of 97