Chapter 2 Operator Panel Operation
2.2 Status Display
2.2.2

Drive/Tape Cartridge Status

The following status types for drives and tape cartridges are displayed. The status types that are listed in
2.4
are added to the status types that are listed in
Table 2.3
Drive/Tape cartridge status
Status name
Initializing
No Tape
Loading
Ready
Write Protected
Rewinding
Reading
Writing
Erasing
Locating
Unloading
Unloaded
Cleaning
Required Clean
Need Clean
Error
FAN Alarm
Media Error
Updating
Power Off
Not Installed
Table 2.4
Drive/Tape cartridge status (details)
Status name
XXX / Not Connect
XXX / Offline
XXX / Trace Saving
XXX / Prevent
FUJITSU Storage ETERNUS LT270 S2 Tape Library User's Guide -Panel Operation-
Table
Indicates that initialization is under way after drive power-on.
Indicates that no tape cartridge is inserted.
Indicates that the drive is being loading.
Indicates that the drive is read/write ready after loading is complete.
Indicates that the loaded tape cartridge is write protected.
Indicates that the tape cartridge is being rewound.
Indicates that the tape cartridge is being read.
Indicates that the tape cartridge is being written to.
Indicates that the tape cartridge is being erased.
Indicates that the tape cartridge is being located.
Indicates that the drive is being unloaded.
Indicates that the unloading is completed.
Indicates that cleaning is under way after a cleaning cartridge is loaded.
Indicates that the drive requires cleaning.
Indicates that the drive requires cleaning.
(In this state, only a cleaning cartridge can be loaded.)
Indicates that an error occurred in the drive.
Its error code is also displayed.
Indicates that the cooling fan in the drive unit has failed.
Indicates that an error occurred in the loaded tape cartridge.
Indicates that the firmware of the drive is being updated.
Indicates that the power is off.
Indicates that no drive is installed.
Indicates that the FC cable is not connected.
Indicates that the drive is offline.
Indicates that fault analysis data (trace data) is being collected automatically after the
occurrence of drive failure.
Indicates that the drive is reserved by the host.
The reserved drive is excluded from the targets of manual drive ejection, and cannot be
ejected.