DIAGNOSTICS
10DEC05
Communications for the MOTION SYSTEM CONTROL BOARD
DG4825-1
Page
32001 - Communications malfunctioned between MCPU and SSC BOARDS
110 of 180
Description: A message from the MASTER CENTRAL PROCESSING UNIT BOARD
Cause 1: The MASTER CENTRAL PROCESSING UNIT BOARD A2 malfunctioned.
Action:
Cause 2: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:
Cause 3: The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action:
32002 - MSC BOARD A1: Internal Communications Error
Description: A malfunction occurred with the RS-232 communications on the MOTION
Cause:
Action:
32003 - MSC BOARD A1: Internal Communications Error
Description: A malfunction occurred with the RS-232 communications on the MOTION
Cause:
Action:
32004 - Communications Error between MCPU and SSC BOARDS
Description: A message was sent to the SLOW SCAN CONTROLLER BOARD A6
A2 did not complete before another message was received.
Do the checkout for the
Do the checkout for the
Do the checkout for the
BOARD
A7.
SYSTEM CONTROL BOARD A1.
The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Do the checkout for the
SYSTEM CONTROL BOARD A1.
The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Do the checkout for the
and a response was not received within 3 seconds.
MASTER CENTRAL PROCESSING UNIT BOARD
MOTION SYSTEM CONTROL BOARD
SLOW SCAN CONTROLLER BOARD A6 and COIL
MOTION SYSTEM CONTROL BOARD
MOTION SYSTEM CONTROL BOARD
Error Codes
A2.
A1.
A1.
A1.