Kodak 4825 Manuals
Manuals and User Guides for Kodak 4825. We have
6
Kodak 4825 manuals available for free PDF download: Diagnostics Manual, Adjustments And Replacements, Theory Manual, Installation Instructions Manual, Preventive Maintenance, Diagrams
Kodak 4825 Diagnostics Manual (180 pages)
Brand:
Kodak
| Category:
Medical Equipment
| Size: 8.36 MB
Table of Contents
Table of Contents
2
Description
10
System Service Diagnostic Screen
10
Functions of the "System Service Diagnostic" Screen
12
Diagnostic Tests
24
Individual Component Control
24
Component Control: Step
28
Light Test
31
Slow Scan Current and Velocity Tests
33
Laser Power
35
Galvo Test
36
PMT Test
39
Galvo Plot
40
Transport
43
Autolooper
45
MCPU Self Test
47
Diagnostic Procedures
49
Checking the Error Logs
49
Checking the Error Frequency Log
50
Checking the Actuation Logs
51
Storing the Error Logs on a Disk
52
Clearing the Error Logs
53
Installing Files from a Disk
54
Displaying the Software Versions
55
Downloading Software to the BOARDS
56
Overview
57
Error Codes
57
Cassette Load
58
10006 - CASSETTE REAR SENSOR S3 DID Not Detect CASSETTE
58
10007 - CASSETTE REAR SENSOR S3 DID Not Detect Loading of
58
Cassette
58
10008 - CASSETTE REAR SENSOR S3 DID Not Clear
59
10009 - CASSETTE LOAD SENSOR S2 DID Not Clear
60
10014 - CASSETTE REAR SENSOR S3 Blocked on Load
61
10016 - Load CASSETTE: Retry Attempt
61
10017 - Eject CASSETTE: Retry Attempt
62
10019 - Eject CASSETTE: Timeout Error
62
10020 - Malfunction at CASSETTE ENTRY SENSOR S1
63
10021 - MSC BOARD A1: Software Malfunction
63
10024 - MSC BOARD A1: Software Malfunction
64
10022 - MSC BOARD A1: Software Malfunction
64
10029 - READER Detected the CASSETTE BAR CODE Label as Backward
64
10030 - READER DID Not Read the CASSETTE BAR CODE
64
Latch/Unlatch Cam
66
11001 - DUPLEX CAM DID Not Move to Home Position
66
11002 - DUPLEX CAM DID Not Move to "PINCH" Position
66
11003 - DUPLEX CAM DID Not Move to "CLAMP/UNLATCH" Position
66
11004 - DUPLEX CAM DID Not Move to "UNCLAMP/LATCH" Position
66
11005 - DUPLEX CAM DID Not Move to "UNPINCH" Position
66
11006 - CAM OUTER SENSOR S11 DID Not Detect Position of DUPLEX CAM
66
11007 - CAM INNER SENSOR S10 DID Not Detect Home Position for DUPLEX CAM
66
11009 - DUPLEX CAM: Move Failed
67
11010 - DUPLEX CAM: Software Command Failed on the MSC BD
67
11014 - DUPLEX CAM: Timeout Error
67
11015 - Move Command Failed Because SLOW SCAN Not at Home Position
67
11016 - MSC BOARD A1: Software Error for DUPLEX CAM
67
11017 - MSC BOARD A1: Software Error for DUPLEX CAM
68
11018 - DUPLEX CAM DID Not Move to Next Position
68
11019 - DUPLEX CAM DID Not Move to "PINCH" Position
68
11020 - DUPLEX CAM DID Not Move to "UNLATCH" Position
68
11021 - DUPLEX CAM DID Not Move to "LATCH" Position
69
11022 - DUPLEX CAM DID Not Move to "UNPINCH" Position
69
Slow Scan Ay
69
12001 - SLOW SCAN EXTRACTION BAR DID Not Move to Home Position
69
12002 - EXTRACTION BAR REFERENCE SENSOR S9 Failed to Activate
70
12003 - PLATE PRESENT SENSOR S5 DID Not Detect PLATE
70
12004 - PLATE PRESENT SENSOR S5 Failed to Activate
71
12009 - Caution! SLOW SCAN MOTOR Drawing too Much Power
71
12013 - SLOW SCAN AY: Timeout Error
72
12012 - SLOW SCAN AY: Timeout Error
72
12014 - MSC BOARD A1: Software Error for SLOW SCAN
72
12100 - SLOW SCAN CONTROLLER BOARD A6: Software Error
72
12103 - SLOW SCAN Stopped During Scan
73
12101 - SLOW SCAN a Velocity Malfunction During Scan
73
12102 - SLOW SCAN Stopped During Scan
73
12104 - SLOW SCAN: Timeout While Moving to SENSOR S9
73
12109 - SLOW SCAN Stopped During Scan
74
12107 - SLOW SCAN: +24 V DC Malfunction During Scan
74
12108 - SLOW SCAN Stopped During Scan
74
12110 - SLOW SCAN DID Not Communicate with the MOTION SYSTEM CONTROL
74
12111 - SLOW SCAN DID Not Move
74
12112 - SLOW SCAN DID Not Move
75
12113 - SLOW SCAN CONTROLLER BOARD A6: NVRAM Malfunctioned
75
12115 - SLOW SCAN CONTROLLER BOARD A6: Software Error
75
12116 - SLOW SCAN CONTROLLER BOARD A6 DID Not Communicate with MSC
75
12121 - SLOW SCAN DID Not Move
76
12120 - SLOW SCAN DID Not Move
76
12122 - SLOW SCAN COIL BOARD A7 Malfunctioned
76
12123 - SLOW SCAN CONTROLLER BOARD A6: Software Error
76
12124 - SLOW SCAN CONTROLLER BOARD A6: Software Error
77
12125 - SLOW SCAN COIL BOARD A7 Malfunctioned
77
12126 - Caution! SLOW SCAN MOTOR Is Overheated
77
12130 - SLOW SCAN CONTROLLER BOARD A6: Software Error
77
12131 - SLOW SCAN CONTROLLER BOARD A6 DID Not Communicate with MSC
77
12202 To 12260 - SLOW SCAN CONTROLLER BOARD A6: “Memory
78
12132 - SLOW SCAN CONTROLLER BOARD A6 DID Not Communicate with MSC
78
12201 - SLOW SCAN CONTROLLER BOARD A6: Programming Error
78
12202 To 12260 - SLOW SCAN CONTROLLER BOARD A6: "Memory
78
Command" Error
78
12896 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Reset
80
12901 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
80
12902 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
81
12903 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
81
12906 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
81
12907 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
82
12915 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
83
12913 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
83
12911 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
83
12908 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
83
12914 - SLOW SCAN CONTROLLER BOARD A6: Unexpected Retry
83
12930 - SLOW SCAN: Unexpected Retry During Current Test
83
12931 - SLOW SCAN: Unexpected Retry During Velocity Test
83
12941 - Unexpected Retry During Communication to MOTION SYSTEM
84
Control Bd
84
Erase Lamps
84
13001 - 13008 Erase Lamp Pairs
84
13009 - All ERASE LAMPS Malfunctioned
85
13010 - Erase Time Exceeds Maximum Allowed
86
13011 - Command to Erase DID Not Occur
86
13012 - MSC BOARD A1: Invalid Command for ERASE LAMPS
86
13013 - MSC BOARD A1: Software Failure During Erase
86
13899 - General Erase Error
86
Power Supply
86
14001 - SLOW SCAN: Malfunction of 24 V Power
86
14002 - STEPPER: Malfunction of 24 V Power
87
14003 - CAM MOTOR M1: Low Power Malfunction
87
14005 - Front DOOR Open
87
14006 - DUPLEX CAM: Initialization Error Due to the PLATE PRESENT SENSOR S5 Reading Blocked When the SLOW SCAN AY Is in the Home Position
88
14008 - SLOW SCAN: Initialization Error
88
14009 - DUPLEX CAM: Initialization Error
88
14010 - Slow Scan Async Reset Error
88
15002 - MCPU BOARD A2: Fatal Error in Software
89
Data Path
89
15001 - MCPU BOARD A2: Fatal Error in Software
89
15003 - MCPU BOARD A2: Communications Error in Software
89
15005 - LASER: Reference Error
89
15006 - Communications Error between MCPU BD A2 and GALVO BD A4
90
15007 - Communications Error between MCPU BD A2 and GALVO BD A4
91
15008 - Start of Scan Timeout
91
15012 - Communications Error between MCPU BOARD A2 and the PC
91
15013 - Image Quality Warning
92
15014 - LASER Power Not Calibrated
92
15015 - PLATE Not Calibrated
92
15016 - the LASER Reference Voltage Is too High
93
15017 - PLATE Not Calibrated
93
15018 - There was an Error Reading or Writing to the PCMCIA Card
93
15040 - Communications Error between MCPU and the PC
93
15800 - Image Resent at NT Reboot
94
15900 - NT Rejected Image at End of Scan. Retransmission Being Attempted
94
Calibration
95
16001 - Calibration Error: DID Not Find START of SCAN Position
95
16002 - Calibration Error: DID Not Find Offset
95
16003 - Calibration Error: DID Not Find Amplitude
95
Allowed
96
16005 - Calibration Error: Routine DID Not Receive Image in the Time
96
16006 - Calibration Error: DID Not Acquire Image
97
16010 - Possible Light Leak
97
16011 - Imaging System Error Occurred During Initialization
97
16012 - PMT/DAS BOARD A5: Calculation Error Occurred During
97
Initialization
97
16013 - Imaging System Contains Out-Of-Range Noise
98
16014 - Imaging System DID Not Zero or PMT DID Not Calibrate
98
16018 - Possible Light Leak
99
16016 - Malfunctioning PMT
99
16017 - Possible Light Leak
99
16019 - Calibration Could Not Find Offset, Rotate GALVO Counterclockwise
99
16020 - Calibration Could Not Find Offset, Rotate GALVO Clockwise
99
16021 - Malfunctioning PMT1: Gain out of Range
100
16022 - Malfunctioning PMT2: Gain out of Range
100
19004 - GALVO AGC Reference Is too High. Suggest Check if GALVO
101
Self Test" for the MASTER CENTRAL PROCESSING UNIT
101
19001 - Check GALVO COMMUNICATIONS CABLE
101
19002 - Check PMT BOARD CABLE and Power
101
19003 - Check the Power to the GALVO BOARD
101
Connected And/Or Adjust AGC
101
19005 - Check the GALVO Reference (too Low)
102
19006 - Memory Self Test Failed. Replace the MCPU BOARD
102
19009 - the LASER Diode off Power Is too High
102
19010 - the LASER Diode on Power Is too Low
102
19011 - PMT BOARD Ramp Test Failed
103
Motion System Control Board
103
22000 - MSC BOARD A1: Fatal Software Error
103
22001 - MSC BOARD A1: Memory DID Not Erase During Download
103
22002 - MSC BOARD A1: Error During Download of MSC Software
103
22003 - MSC BOARD A1: Checksum of Main Application Failed
104
22011 - MSC BOARD A1: Error During Download of MSC Software
107
22010 - MSC BOARD A1: Error During Download of MSC Software
107
Motion System Control Board Rtxc
107
29001 - 29008 - MSC BOARD A1: Software Malfunctioned
107
Motion System Control Board
108
30002 - 30033 - MSC BOARD A1: Software Malfunctioned
108
32003 - MSC BOARD A1: Internal Communications Error
110
32001 - Communications Malfunctioned between MCPU and
110
Communications for the MOTION SYSTEM CONTROL BOARD
110
32002 - MSC BOARD A1: Internal Communications
110
32004 - Communications Error between MCPU and SSC BOARDS
110
32005 - Communications Error between MCPU and SSC BOARDS
111
47500 - 47504 - Internal Communications to UPS Failed
112
Shutdown Management
112
47001 - Communications to MCPU BD Failed During Shut down
112
47002 - Internal Communications Failure
112
47003 - Internal Communications to UPS Failed
112
47510 - 47511 - Internal Communications Failure to UPS1
112
47520 - 47522 - Internal Communications Failure to UPS1
113
47550 - the BATTERY in UPS1 Is too Low. System will be Shutdown in 1
113
47551 - Unable to Establish Communications with UPS1
113
47950 - Display Only - no Log Message
113
47951 - Display Only - no Log Message
114
47952 - Display Only - no Log Message
114
47962 - Display Only - no Log Message
115
Disk Manager
115
49001 - Image Files Have Been Deleted
115
55100 - Error on the Options Diskette or this Is Not a Valid Options
116
Diskette
116
55101 - Could Not Open Files on the Options Diskette. Try Another Options
116
55102 - Pentium III Identification Not Enabled on this Pentium III Class
116
Installation
116
Diskette
116
10Dec05 Dg4825-1
116
Machine
116
55103 - Could Not Open Files on the Options Diskette
117
55104 - Error Updating the Options on the CR 825/850 SYSTEM
117
55105 - Could Not Allocate Essential Memory
117
55106 - the Options on this Diskette Are Already Enabled on this System
117
55107 - this Options Diskette Has Been Used on Another Device
117
55109 - Error Occurred While Trying to Update the Options on the UNIT
117
55110 - Could Not Determine What Product We Are Running on
118
55111 - the Options Diskette Is Not Valid for this Product
118
55112 - Error Obtaining Adapter Name on Pentium 4 Class Machine
118
55113 - Error Obtaining MAC Address for Card Name Specified in
118
Adaptername in General Equipment on Pentium 4 Class Machine
118
Troubleshooting
119
Initialization Errors
119
Power-On Self-Test" (POST) Errors
119
Software Loading Errors
120
Application Software Errors
121
Dark TOUCH SCREEN
121
Image Quality
121
Checkout Procedures
122
Cassette Handling Ay
122
Duplex Cam
122
Cam Motor M1
128
Plate Present Sensor S5
129
Interlock Switch S8
132
Extraction Bar Sensor S9
134
HOOKS on the EXTRACTION BAR
136
CAM SENSORS S10 and S11
137
Boards
139
Motion System Control Board A1
139
Master Central Processing Unit Board A2
140
Digitizer Board A3
143
Galvo Board A4
145
Pmt/Das Board A5
147
SLOW SCAN CONTROLLER BOARD A6 and COIL BOARD A7
148
Laser Driver Board A17
152
Power
154
Power Supply Ps1
154
Transformer T1
156
Advertisement
Kodak 4825 Adjustments And Replacements (160 pages)
Brand:
Kodak
| Category:
Medical Equipment
| Size: 16.94 MB
Table of Contents
Table of Contents
2
Interlock Switch
4
Top Cover
6
Galvo Board
8
Galvo Rotation
18
Fold Mirror
24
Collector Ay
33
Intermediate Plate
37
Cam Sensor Board A8
41
Cam Motor Ay
44
Sled Cam Follower
47
Clamp Bar
52
Cassette End Stop
56
Rear Cassette Sensor
58
Extraction Bar Home Position
61
Plate Positioning Ay
66
RIGHT and LEFT PLUSH AY - Alignment
73
LEFT PLUSH AY - Vertical Position
77
Internal Bar Code Reader
81
Cassette Load Cradle
86
Replacements
88
GALVO and BLOCK AY
88
Optics Module
90
Pmt/Das Board
92
Pmts and COLLECTOR AY
94
Fold Mirror
96
Cassette Handling Ay
97
Cam Motor Ay
101
HOOK YOKE AY and HOOK YOKE BEARING
103
Idler Roller Ay
104
Cassette Drive Ay
107
Cassette Drive Rollers
109
Cassette Drive Motor Ay
111
Left Plush Ay
112
Right Plush Ay
114
Extraction Bar
116
Slow Scan Ay
117
Extraction Bar Reference Sensor S9
119
Plate Present Sensor S5
120
COIL BOARD A7, ENCODER and SLOW SCAN ROTOR
122
Plate Positioning Ay
126
Erase Lamp Ay
127
Cpu
129
Hard Drive
132
Additional Service Procedures
139
Opening and Removing COVERS and PANELS
139
Restoring the Purchased Options
143
Restoring the Configuration
144
Setting the Laser Calibration Voltage
144
Calibration for the CR 825/850 SYSTEM
145
Kodak 4825 Theory Manual (120 pages)
Brand:
Kodak
| Category:
Medical Equipment
| Size: 2.05 MB
Table of Contents
Table of Contents
2
Equipment Description
5
Features and Functions
5
Main Subsystems
10
Radiography Theory
13
Comparison of Film/Screen and Computed Radiography (CR)
13
Overview of CR Technology
17
Operations
17
Exposing the STORAGE PHOSPHOR SCREEN
17
Stimulating the PHOSPHOR
19
Changing Light Energy to an Analog Signal
20
Changing Analog Signals to Digital Signals
21
Processing the Digital Image
22
Sequence of Operation
23
Overview of Workflow Using the CR 825/850 SYSTEM
23
Before Loading the CASSETTE
24
Loading the CASSETTE
24
Fastening the PLATE
26
Preparing to Scan
27
Scanning the SCREEN
28
Erasing the SCREEN
29
Inserting the PLATE Back into the CASSETTE SHELL
30
Removing the CASSETTE
30
Storage Phosphor Cassette
32
Overview
32
Size and Resolution of SCREENS
34
Fast Scan / Slow Scan Directions
36
Image Matrix Size
37
Reading the BAR CODE LABEL of the CASSETTE
39
Cassette Handling
41
Overview
41
Duplex Cam Ay
42
Cassette Entry
46
Cassette Transport
49
Plate Handling
52
Optical
54
Overview
54
Laser Galvo
55
COLLECTOR and PHOTOMULTIPLIER TUBE (PMT)
62
Scan/Erase
68
Overview
68
Plate Positioning Ay Lead Screw Extraction Bar Reference Sensor S9
69
Plate Present Sensor S5
73
Slow Scan Motor
73
Encoder
77
Erase Ay
78
Lamp Current Sensors Cs1 - Cs5
79
Imaging Sequence
80
Overview
80
Scanning the SCREEN - Slow Scan/Fast Scan
81
Obtaining the Image Data
83
Processing the Data
86
Processing the Image
87
Logic and Control
89
Overview
89
Operator Input Components
90
Boards
93
Distribution of Images to the Network
102
Overview
102
Sequence of Operation
103
Power Distribution
105
Overview
105
Power Supply
106
Advertisement
Kodak 4825 Installation Instructions Manual (72 pages)
Brand:
Kodak
| Category:
Medical Equipment
| Size: 4.59 MB
Table of Contents
Table of Contents
2
Safety
4
Necessary Materials
6
Tools
6
Installation
7
Unpacking the Equipment
7
Installing the Equipment
21
Energizing the System
28
Obtaining a "Session ID
29
Doing the Calibration for the TOUCH SCREEN
29
Setting the Site Parameters
30
Setting the "User Name" and "Password
31
Installing and Setting up Optional Features
33
Setting the "Global" Parameters
34
Setting the HIS/RIS Parameters
39
Adding a PRINTING DEVICE
43
Adding a STORAGE DEVICE
51
Setting the Profile Destination Configuration
54
Enabling the BAR CODE READER
55
Setting the Requirements Fields
59
Configuring the MONITOR
59
Doing the Configuration for the Kodak Directview CR LONG-LENGTH IMAGING SYSTEM
60
Storing the Setup Data
61
Installing the Kodak REMOTE PATIENT DATA ENTRY STATION (RPDES)
62
Setting the Configuration for the RPDES
63
Kodak 4825 Preventive Maintenance (30 pages)
Brand:
Kodak
| Category:
Medical Equipment
| Size: 2.9 MB
Table of Contents
Table of Contents
2
Necessary Materials
3
Maintenance Plan
4
Checking the Error Logs
5
Checking the Scan Operation
5
Cleaning the FILTER - 2.4 Ghz PC Only
6
Cleaning the PMT/DAS BOARD
7
Cleaning the Pmts and COLLECTOR AY
8
Cleaning and Applying Lubricant to the CASSETTE HANDLING AY
9
Cleaning the BAR CODE READER
11
Cleaning the EXTRACTION BAR
12
Cleaning and Applying Lubricant to the SLOW SCAN SLIDES
13
Cleaning the ERASE LAMP AY
14
Cleaning the System
15
Installing the New LIGHT SEALS on the TOP COVER
16
Installing the New CLAMP BAR PLUSH
17
Installing the New RIGHT and LEFT LIGHT BAFFLES
19
Installing the New REAR CLIP AY
20
Installing the New LIGHT SEAL PLUSH
21
Installing the New LEAF SPRINGS
23
Installing the New FIXED LIGHT SEAL PADDLE
24
Installing the New LIGHT SEAL PADDLE
25
Installing the New CASSETTE DRIVE ROLLERS
26
Checking the CAM and MOTOR
27
Checking the Adjustments
28
Checking the Operation
29
Kodak 4825 Diagrams (12 pages)
Brand:
Kodak
| Category:
Medical Equipment
| Size: 0.34 MB
Table of Contents
Table of Contents
2
Block
3
System Connections
3
Electrical
4
System Overview 1 of 2
4
System Overview 2 of 2
5
Erase Assembly
6
Image Scan System
7
Motion System Control Board A1
8
COMPUTER, DISPLAY and BAR CODE READER
9
Functional
10
Power Distribution
10
Advertisement
Related Products
Kodak Advantix 4800ix
Kodak 4800 Series
Kodak X-Omat 480 RA
Kodak 4860
Kodak 4200-J
Kodak 4000 series
Kodak 40FHDXSMART
Kodak 409X5061
Kodak 439X5081
Kodak 429X5071
Kodak Categories
Digital Camera
Scanner
Printer
All in One Printer
Projector
More Kodak Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL