10DEC05

11021 - DUPLEX CAM did not move to "LATCH" position

DG4825-1
Page
Cause 1: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
69 of 180
Action:
Cause 2: The DUPLEX CAM malfunctioned.
Action:

11022 - DUPLEX CAM did not move to "UNPINCH" position

Cause 1: The DUPLEX CAM malfunctioned.
Action:
Cause 2: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action:

SLOW SCAN AY

12001 - SLOW SCAN EXTRACTION BAR did not move to Home Position

Cause 1: The EXTRACTION BAR malfunctioned.
Action:
Cause 2: The EXTRACTION BAR SENSOR S9 malfunctioned.
Action:
Do the checkout for the
Do the checkout for the
Do the checkout for the
Do the checkout for the
1.
Remove any obstructions in the path of the EXTRACTION BAR.
2.
Check the SLOW SCAN MOTOR.
3.
Do the checkout for the
BOARD
A7.
4.
Check the
EXTRACTION BAR HOME POSITION
Do the checkout for the
MOTION SYSTEM CONTROL BOARD
CASSETTE HANDLING
CASSETTE HANDLING
MOTION SYSTEM CONTROL BOARD
SLOW SCAN CONTROLLER BOARD A6 and COIL
EXTRACTION BAR SENSOR
A1.
AY.
AY.
A1.
S9.