DIAGNOSTICS
10DEC05
INTERLOCK SWITCH S8
DG4825-1
Page
132 of 180
2 TERMINALS
H194_0041GCA
H194_0041GC
6
Is the resistance correct?
1.
2.
FRONT DOOR
INTERLOCK SWITCH S8
SWITCH ACTUATOR
Yes
Connect the 2 TERMINALS to
the INTERLOCK SWITCH S8.
Continue with
Step
7.
1
Check:
•
•
LATCH
•
•
•
•
2
Disconnect the 2 TERMINALS from the
INTERLOCK SWITCH S8.
3
Connect the MULTIMETER to the 2
TERMINALS.
4
Set the MULTIMETER to "Ω".
5
Measure the resistance of the
INTERLOCK SWITCH S8:
INTERLOCK SWITCH
1.
Install a new INTERLOCK
SWITCH S8.
2.
Continue with
Checkout Procedures
FRONT DOOR is fully closed
SWITCH ACTUATOR is in the
correct position
SWITCH ACTUATOR and
INTERLOCK SWITCH S8 are in
alignment
LATCH is adjusted correctly
condition of the INTERLOCK
SWITCH S8
wires are connected to the
INTERLOCK SWITCH S8
S8
Actuated
Not Actuated
No
Step
7.
W
0 - 1
≥ 1000