ABB IRC5 Compact Product Manual page 80

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

2 Installation and commissioning
2.6.8 The MOTORS ON/MOTORS OFF circuit
Continued
U
Function of the MOTORS ON/MOTORS OFF circuit
The circuit monitors all safety related equipment and switches. If any of the switches
are opened, the MOTORS ON/MOTORS OFF circuit switches the power to Motors
Off.
As long as the two chains not are in an identical state, the robot will remain in
MOTORS OFF mode.
Connection of safety chains
The diagram below shows the dual channel safety chain.
The supply from internal 24V and 0 V is displayed. For external supply of GS and
AS check the circuit diagram.
xx1600000281
Technical data per chain
Limit switch
Continues on next page
80
SS (Input from, for example, SafeMove board)
X15.4
Opto
SS1
isol.
X15.2
Opto
GS1
isol.
Opto
AS1
isol.
X15.5
Opto
SS2
X15.3
isol.
GS2
AS2
Load: 300 mV
Max. voltage drop: 1 V
© Copyright 2009-2020 ABB. All rights reserved.
Terminal
Location
A21
X5
X15
A21
Product manual - IRC5 Compact
3HAC047138-001 Revision: M

Hide quick links:

Advertisement

Table of Contents
loading