ABB IRC5 Compact Product Manual page 183

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

Removing DSQC1016/1023
Use this procedure to remove the Connected Services box, version DSQC1016/1023.
1
2
3
4
5
6
7
8
9
10
Product manual - IRC5 Compact
3HAC047138-001 Revision: M
Action
DANGER
Before any work inside the cabinet, read the safety
information in section
Electrical safety on page
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
is sensitive to ESD on page
Remove the top and front covers.
Disconnect the antenna.
Remove the cable and connectors connected to:
Safety board
Ethernet switch (if installed)
Connected Services Box
Remove the two attachment screws, and push the
safety board unit backwards to release the latches.
Pull the latch (A) to the left, and push the Connected
Services box out.
If installed, remove the Ethernet switch.
Remove the safety board from the assembly.
Remove the connector in the Connected Services
box.
© Copyright 2009-2020 ABB. All rights reserved.
4.17 Replacement of Connected Services box
Information
32.
The unit
49.
See
controller on page
xx1400001462
A
xx1400001460
4 Repair
Continued
Opening the IRC5 Compact
88.
Continues on next page
183

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents