2 Installation and commissioning
2.11.2 Installation of external enabling device
Continued
Performance of IRC5 original enabling device chain
The safety-related performance of the enabling device chain, without the external
enabling device, is as follows:
104
with IRC5's enabling device chain is above 55 years. See safety related
performance for the enabling device chain below.
•
MTTF
for IRC5 enabling device chain is 80 years.
d
•
IRC5's enabling device chain's calculated average probability of dangerous
failure per hour (PFH
•
IRC5's enabling device chain's design and structure is category 3.
•
IRC5's enabling device chain's Diagnostic Coverage is medium (90% < DCavg
< 99%).
•
The Common Cause Failure (CCF) is met according to the standard
requirements.
© Copyright 2009-2020 ABB. All rights reserved.
) is 6.62x10E-08.
d
Product manual - IRC5 Compact