ABB IRC5 Compact Product Manual page 200

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

4 Repair
4.19.3 Replacement of line filter
Continued
Removal
Use the following procedure to remove the line filter.
1
2
3
4
5
6
Continues on next page
200
Action
DANGER
Before any work inside the cabinet, read
the safety information in section
al safety on page
32.
Remove the cover of the cabinet.
Disconnect connector X1 from the sys-
tem power supply.
Disconnect the ground connection.
Disconnect and remove the safety board
unit to be able to access the secondary
side of the line filter.
Disconnect the cables from L1', L2' on
the secondary side of the line filter.
© Copyright 2009-2020 ABB. All rights reserved.
Note/illustration
Electric-
See
Opening the IRC5 Compact controller on
page
88.
xx1400002853
A Connector X1
B Ground connection
See
Replacement of Connected Services box
on page
180.
A
xx1400002854
A Line filter connections
Product manual - IRC5 Compact
A
B
3HAC047138-001 Revision: M

Hide quick links: