2 Installation and commissioning
2.6.1.3 Connectors on the computer unit
Continued
LAN 2 can only be used as private network to the IRC5 controller.
Isolated LAN 3 or LAN 3 as part of the private network (only for RobotWare 6.01 and later)
The default configuration is that LAN 3 is configured as an isolated network. This
allows LAN 3 to be connected to an external network, including other robot
controllers. The isolated LAN 3 network has the same address limitations as the
WAN network.
xx1500000393
An alternative configuration is that LAN 3 is part of the private network. The ports
Service, LAN 1, LAN 2, and LAN 3 then belong to the same network and act just
as different ports on the same switch. This is configured by changing the system
parameter Interface, in topic Communication and type Static VLAN, from "LAN 3"
to "LAN". See Technical reference manual - System parameters.
xx1500000394
USB ports
The USB ports are intended for connecting USB memory devices.
58
Note
The isolated LAN 3 cannot be used to connect to any HMI device (RobotStudio,
Robot Web Services, or PC SDK client) since it does not support the protocol
needed for communication.
Robot Controller
Isolated
Private
LAN 3
Service
LAN 2
LAN 3
LAN 1
Robot Controller
Private
Service
LAN 1
LAN 2
LAN 3
Note
For more information and examples of connecting to different networks, see
Application manual - EtherNet/IP Scanner/Adapter or Application
manual - PROFINET Controller/Device.
Note
It is recommended to use the USB ports USB
for connecting USB memory devices.
The USB ports on the X11 connector are intended for internal use.